eGospodarka.pl
eGospodarka.pl poleca

eGospodarka.plNieruchomościGrupypl.misc.budowaniekociol dla domu 175m2Re: kociol dla domu 175m2
  • Path: news-archive.icm.edu.pl!news.rmf.pl!agh.edu.pl!news.agh.edu.pl!news.onet.pl!not
    -for-mail
    From: "Tomek" <a...@i...pl>
    Newsgroups: pl.misc.budowanie
    Subject: Re: kociol dla domu 175m2
    Date: Thu, 7 Oct 2010 12:23:07 +0200
    Organization: http://onet.pl
    Lines: 17
    Message-ID: <i8k72d$t7a$1@news.onet.pl>
    References: <i8jpi6$9mp$1@inews.gazeta.pl> <i8k1l8$cjb$1@news.onet.pl>
    <i8k3a9$b87$1@inews.gazeta.pl>
    NNTP-Posting-Host: 87-205-11-43.ip.netia.com.pl
    X-Trace: news.onet.pl 1286446989 29930 87.205.11.43 (7 Oct 2010 10:23:09 GMT)
    X-Complaints-To: n...@o...pl
    NNTP-Posting-Date: Thu, 7 Oct 2010 10:23:09 +0000 (UTC)
    X-Priority: 3
    X-MSMail-Priority: Normal
    X-Newsreader: Microsoft Outlook Express 6.00.2900.5931
    X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.5994
    X-RFC2646: Format=Flowed; Response
    Xref: news-archive.icm.edu.pl pl.misc.budowanie:405205
    [ ukryj nagłówki ]

    > tak jak napisałem było 20kW, jednak w oryginale projekt był zmieniany
    > doprojektowano piwnice ok 90m2.
    >
    > i dlatego pytam czy te 6 kW więcej będzie wporządku

    Piwnica bedzie ogrzewana? Tak pi razy drzwi to przyjmuje sie 100W/m2
    powierzchni ogrzewanej i jest to juz z zapasem jesli dom jest nowy
    prawidlowo wybudowany wg obowiazujacych norm. Jak chcesz dokladnie, to
    niestety czeka Cie OZC, co nie jest jakies trudne tylko bardzo czasochlonne.
    Wg mnie 26kW w zupelnosci wystarczy. U mnie jest 100m2 + 56m2 piwnicy
    nieogrzewanej, kociol mam ustawiony na ok 12kW i nigdy nie braklo mocy.
    Ogrzewam tez nim CWU.

    --
    Tomek